Drift Sensors - Lexmark C77x Service Manual

C77/c78 series
Hide thumbs Also See for C77x:
Table of Contents

Advertisement

5061
Press Back (

Drift Sensors

This check is used to display the status of the thermal system used to compensate for printhead drift.
To perform the test:
1.
Select ALIGNMENT from Diagnostics mode.
2.
Select Drift Sensors.
The following screen is displayed when the test is selected:
Black
Magenta
Cyan
Black Testing... appears, followed by the results. For example:
Values:
Value:
OK
Error
Open
Short
Range
Number
If Error appears, replace the system board. See
If a number, Open, or Short appears, check the following:
a.
Check the cable of the appropriate thermistor (cyan, magenta, yellow, or black) to make sure it is
installed correctly to the system board and to the thermistor board. If correct, go to step b.
b.
Check the continuity of the appropriate cable. Replace the cable if there is no continuity. If continuity
is correct, go to step c.
c.
Replace the appropriate thermistor assembly. If this does not fix the problem, replace the system
board.
To exit the test, press Back (
3-12
Service Manual
) to exit the ALIGNMENT MENU.
Drift Sensors
OK
Results 26
Description:
Communication is good
RIP to A/D communication error
Open thermistor error
Short thermistor error
Range error
Detected temperature in Celsius of last
reading. Indicates the system is functioning
properly.
) or Stop (
Yellow
"System board removal" on page
).
Drift Sensors
4-89.