Figure 1 12 Storage server LEDs
1. Front UID/LED switch
3. NIC 1 activity LED
5. Power LED switch
Table 76 Storage server LED descriptions
LED
Front UID/LED switch
System health LED
NIC 1 activity LED
NIC 2 activity LED
Power LED switch
You can also check the Hardware Information tab in the CMC (select Diagnostics for the applicable
storage system and then select the Hardware Information tab). If a RAID controller is not working,
it will not be visible on the Hardware Information tab.
Because there are two RAID controllers in the P4900 G2, it is important to know which one is
being replaced. The RAID controller that manages drives 1–4 and is the OS partition is installed
in the PCIex16 slot of the riser
controller that manages drives 5–8 is installed in the bottom PCIex8 slot and is called Card 2
(Figure 1 14 (page
250)). Review the Alarms section of the CMC to determine if any alarms have
been generated for the cache module or battery.
2. System health LED
4. NIC 2 activity LED
Description
Steady blue: Identification
Flashing blue: The system is being remotely managed
Off: No identification
Steady green: Healthy
Red: Critical error
Amber: Non-critical error
Steady green: Linked to the network
Flashing green: Linked to and activity on the network
Off: No connection
Steady green: Linked to the network
Flashing green: Linked to and activity on the network
Off: No connection
Steady green: The system has AC power and is turned on
Steady amber: The system has AC power but in standby
mode
assembly(Figure 1 13 (page
250)) and is called Card 1. The RAID
Replacing the RAID controller 249