Planning Fibre Channel Server Connections To Management Groups; Adding A Fibre Channel Server Connection; Manually Configuring A Fibre Channel Initiator - HP StoreVirtual 4000 User Manual

10.0 hp lefthand storage user guide (ax696-96202, november 2012)
Hide thumbs Also See for StoreVirtual 4000:
Table of Contents

Advertisement

Planning Fibre Channel server connections to management groups

Add each server connection that needs access to a volume to the management group containing
the volume. After you add a server connection to a management group, you can assign the server
connection to one or more volumes or snapshots.
NOTE:
A server connection can be configured for both iSCSI and Fibre Channel connectivity.
However, there must be only one connection to a volume by a server.
Table 64 Characteristics of Fibre Channel server connections
Item
Name
Description
Controlling Server IP Address
Unassigned Initiator WWPN
Assigned Initiator WWPN

Adding a Fibre Channel server connection

1.
In the navigation window, log in to the management group.
2.
Click Management Group Tasks, and select New Server.
3.
If this server is only used for Fibre Channel connectivity, clear Allow access via iSCSI.
NOTE:
the iSCSI tab.
4.
Click the Fibre Channel tab.
5.
Enter a name and optional description for the server connection.
6.
If you are taking VMware application-managed snapshots, enter the Controlling Server IP
Address.
7.
Select the port names to assign to the server from the Unassigned Initiator WWPN list.
NOTE:
from the same initiator.
8.
Click Assign.
9.
Repeat this step for all the port names you want to assign to this server.
10.
Click OK when you are finished.

Manually configuring a Fibre Channel initiator

If the initiator for which you are creating the server connection is not logged in to the fabric, and
you know the WWPN, then you can manually add that initiator.
1.
In the navigation window, log in to the management group.
2.
Click Management Group Tasks, and select New Server.
If you want to leave iSCSI access allowed, you must add the initiator node name to
Use the ports from the Fibre Channel host initiator. You should only use the ports
Description and Requirements
Name of the server that is displayed in the CMC. The server
name is case sensitive and cannot be changed after the
server is created.
Optional: Description of the server.
Not used for the Application Aware Snapshot Manager
on Windows.
Required for the Application Aware Snapshot Manager
on VMware. Use the IP address of the Microsoft Windows
server that is hosting the vCenter Server.
Optional for using VSS on Windows servers.
Ports on the Fibre Channel initiators that are not assigned
to a server.
Ports on the Fibre Channel initiators that are assigned to
a server.
Planning Fibre Channel server connections to management groups 201