Table 31 iSCSI or iSCSI/FCoE module log messages (continued)
41096
QLBA_DisplayTargetOperationStatus:
PCI Error, Status 0x%.2x
41 106
QLBA_DisplayInitiatorOperationStatus:
DMA Error, Status 0x%.2x
41 107
QLBA_DisplayInitiatorOperationStatus:
Transport Error, Status
0x%.2x
41 1 1 1
QLBA_DisplayInitiatorOperationStatus:
Data Overrun, Status 0x%.2x
41234
QLIS_LoginPduContinue:
Operation failed. Initiator
0x%x, TPB status 0x%x
41238
QLKV_ValidateLoginTransitCsgNsgVersion
failed (status 0x%x)
41257
QLIS_LoginPduContinue:
Invalid initiator name.
Initiator:
41265
QLIS_LoginPduContinue:
Target not configured for
Portal
41267
QLIS_LoginPduContinue:
Target not found. Target
name:
41268
QLIS_LoginPduContinue:
Missing target name
41270
QLIS_LoginPduContinue: TSIH
is 0 but InitiatorName
key/value not provided
41272
QLIS_LoginPduContinue:
CONN_STATE_IN_LOGIN, Unknown
InitTaskTag
41283
QLIS_LoginPduContinue: TSIH
0x%x out of range
41284
QLIS_LoginPduContinue:
Session does not exist,
invalid TSIH 0x%x
41353
QLIS_LoginPduContinue:
Session does not exist,
invalid TSIH 0x%x
41354
QLIS_LoginPduContinue:
Unexpected CHAP key detected
App
Error
Process control block status indicates that a
peripheral component interface/interconnect (PCI)
error occurred during a target operation.
App
Error
Process control block status indicates that a direct
memory access (DMA) error occurred during an
initiator operation.
App
Error
Process control block status indicates that a transport
error (protocol) occurred during an initiator
operation.
App
Error
Process control block status indicates that a data
overrun error occurred during an initiator operation.
App
Error
iSCSI login failed between receipt of protocol data
unit (PDU) and request for the data segment.
App
Error
iSCSI login failed due to unsupported version
number in received login PDU.
App
Error
iSCSI login PDU contains invalid initiator name. The
format and character set used to form the initiator
name is invalid.
App
Error
iSCSI target login was attempted to a portal (iSCSI1
or iSCSI2) on which the target is not presented.
App
Error
iSCSI login PDU received for a target with a target
name unknown to the module.
App
Error
iSCSI login PDU received without a target name for
a normal session.
App
Error
iSCSI login PDU received without an initiator name
key/value.
App
Error
iSCSI login PDU received with an incorrect initiator
task tag for a session which is partially logged in.
This would occur if a login PDU other than the initial
login PDU used an initiator task tag which was
different than the initiator task tag provided in the
initial login PDU.
App
Error
iSCSI login PDU was received with a target session
identifying handle (TSIH) out of range. This would
occur if the iSCSI initiator attempting the login failed
to used the TSIH value provided in the Target Login
Response PDU (module is target) in subsequent login
PDUs.
App
Error
iSCSI login PDU was received with an invalid TSIH
value. The TSIH is invalid because there is no
session with that TSIH value. This would occur if the
iSCSI initiator attempting the login failed to used
the TSIH value provided in the target login response
PDU (module is target) in subsequent login PDUs.
App
Error
iSCSI login rejected due to a CHAP authentication
error.
App
Error
iSCSI login rejected due to a CHAP key error.
267