Table 23 Error Messages (continued)
Status code value
128
OCP Error
129
Mirror Temporarily Offline
130
Failsafe Mode Enabled
131
Drive FW Load Abort Due to
VRaid0 Vdisk
132
FC Ports Unavailable
133
Only Two Remote Relations Are
Allowed
134
The Requested SRC Mode is Not
Possible
135
Source Group Discarded, but the
Destination Group NOT
Discarded
136
Invalid DRM Group Tunnel
Specified
137
Specified DRM Log Size Too
Small
138
Invalid Disk Group Specified
139
DRM Group is Already
Read-Only
140
DRM Group is Already
Active-Active
141
DILX Is Already Running
142
DILX Is Not Running
143
Invalid User Defined Log Size
144
Invalid Second Handle Paramed
145
DRM Group Already Auto
Suspended
172 Error messages
Meaning
EVA 6400/8400 only. A generic error was
detected with the OCP interface.
The virtual disk is not mirrored to the other
controller.
Cannot perform operation because FAILSAFE
is enabled on Group.
The drive firmware cannot be downloaded
to the drive because it is being used for
RAID0 data. One or more RAID0 virtual
disks would be inoperable if the drive were
to be loaded.
There is a diagnostic problem with the
indicated port.
Only two remote relationships are allowed.
The existing drive configuration does not
support the requested SRC mode.
This error is no longer supported.
This error is no longer supported.
This error is no longer supported.
The disk group requested for the attempted
command is not valid.
Data replication group is already read-only.
Data replication group is already
active-active.
The requested operation cannot be
completed while Disk In Line Exerciser is in
progress.
Disk In Line Exerciser cannot be stopped
because it is not running.
Invalid user defined log size.
Invalid data replication group identifier
specified.
Data replication group already auto
suspended.
How to correct
Ensure other OCP is on and try again.
If the problem persists, report the error
to product support.
Ensure other controller is operative.
Disable Failsafe mode on Group.
Migrate RAID0 data to another disk
group or a more protective
redundancy before retrying the drive
update.
Report the error to product support.
Need to reconfigure configuration to
only have two remote destinations.
Report the error to product support.
Report the error to product support.
Report the error to product support.
Report the error to product support.
Retry command using an appropriate
disk group identifier.
Disable read-only mode in group.
Disable active-active mode in group.
Retry command after DILX is complete.
No corrective action required.
Reissue operation with a valid log size
Retry the command with an existing
data replication group.
Unsuspend group and reissue
operation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eva p6300Eva p6500

Table of Contents