Configuring the iRMC S2/S3 via SCCI and scripted configuration

12.2.2 Scripted configuration of the iRMC S2/S3

This section describes provides information on the following topics:
– SCCI commands supported by the iRMC S2/S3.
– Using various script languages for scripted configuration of the iRMC S2/S3.
– Generating encrypted passwords with the iRMC_PWD.exe program.

12.2.2.1 List of SCCI commands supported by the iRMC S2/S3

The SCCI commands supported by the iRMC S2/S3 are shown in
SCCI OpCode SCCI Command String
0xE002
ConfigSpace
0x0111
PowerOnCabinet
0x0112
PowerOffCabinet
0x0113
PowerOffOnCabinet
0x0204
ResetServer
0x020C
RaiseNMI
RequestShutdownAndOff
0x0205
0x0206
RequestShutdownAndReset
0x0209
ShutdownRequestCancelled
0x0203
ResetFirmware
ConnectRemoteStorageServer
0x0250
Table 19: SCCI commands supported by the iRMC S2/S3
420
Description
ConfigSpace Write
Power On the Server
Power Off the Server
Power Cycle the Server
Hard Reset the Server
Pulse the NMI (Non Maskable Interrupt)
Graceful Shutdown, requires running
Agent
Graceful Reboot, requires running Agent
Cancel a Shutdown Request
Perform a BMC Reset
Connect or Disconnect a standalone
Remote Storage Server