Fujitsu Remote Management User Manual page 194

Serverview suite irmc s2/s3 - integrated remote management controller
Table of Contents

Advertisement

Power Management
0 Watt Technology
I
Please note:
– This feature is only supported by the iRMC S3.
– This feature is not supported for all PRIMERGY servers.
The "0 Watt Technology" feature allows you to reduce the server's standby
power consumption to 0 watts. Every time the server is powered off, the server's
standby power consumption is reduced to 0 Watt (0 Watt mode).
I
In the 0 Watt mode, the server can no longer be managed remotely. The
server can only be powered on by pressing the Power button or the PSU
Primary Resume button.
However, by applying the Scheduled option (see
specify a time interval at which the PSU is awoken from 0 Watt mode and
thus both remote management and Wake-on-LAN (WOL) can be used.
Figure 107: Power Options page, 0 Watt Technology
Disabled
Disables 0 Watt mode and remains in / switches to the standard power
on/off mode. The server can be managed remotely at any time.
194
page
196) you can
iRMC S2/S3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents