Scci-Compliant Signaling Command - Fujitsu Remote Management User Manual

Serverview suite irmc s2/s3 - integrated remote management controller
Table of Contents

Advertisement

12.1.2.4 SCCI-compliant signaling command

10 02 - Write to System Display
This command is used to write characters to the LocalView display (if
connected).
Request Data
Response Data
iRMC S2/S3
IPMI OEM Commands supported by the iRMC S2/S3
-
B8
NetFnlLUN: OEM/Group
-
10
Cmd : Command Group Fan Test
1:3
80 28 00
4
02
Command Specifier
5
Object Index: : Line on Display to write on.
6:7
Value ID (not used)
8
Length Number of characters to write, incremented by
one. (The string need not be null-terminated; characters
exceeding the length of a display line are truncated.)
9
Attribute:
0 = Write String left aligned.
1 = Write String centered.
10:10+n
Characters to write to the display; string need not be null-
terminated.
-
BC
-
10
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first
IANA-Enterprise-Number FTS, LS byte first
395

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents