01 16 - Get Power Off Source
This command returns the reason for the most recent Power Off. The possible
reasons are listed below.
Request Data
Response Data
Power off
Description
Source
0x00
Software (SWOFF, power off by command)
0x01
Power switch (on the front panel or keyboard)
0x02
AC power fail
0x03
Clock or timer (hardware RTC or software timer)
0x04
Fan failure
0x05
Critical temperature
0x08
Final power-off after repeated watchdog timeouts
0x0C
Final power-off after repeated CPU errors
0x1D
Powered off by remote control via remote manager
iRMC S2/S3
IPMI OEM Commands supported by the iRMC S2/S3
-
B8
NetFnlLUN: OEM/Group
-
01
Cmd : Command Group Communication
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
16
Command Specifier
-
BC
-
01
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first
3
01
Data Length
4
Power off Source:
Cause of last power off