8.9

Machine faults

Error-
Description
code
1051
Sewing motor timeout
1052
Sewing motor
overcurrent
1053
Sewing motor
overvoltage
1055
Sewing motor
overload
1056
Sewing motor
overheat
1058
Sewing motor speed
1059
(inverted)
1062
Sewing motor IDMA
Autoincrement
1205
Sewing motor not in
the position thread
lever high
1301
Sewing motor
Referencing error
1302
Sewing motor power
source error
1342
Sewing motor failure
1344
2101
Step motor X-Axis
Timeout Referencing
2152
Step motor X-Axis
overcurrent
2153
Step motor X-Axis
overvoltage
Possible cause
- Cable to sewing motor
- Reference switch faulty
- Sewing motor faulty
- Mechanical parts
rough-running
- Sewing motor cable faulty
- Sewing motor faulty
- Control faulty
- Software not compatible
to the control unit version
(A/Bxx.x)
Mains voltage too high
- Sewing motor blocked
/rough-running
- Sewing motor faulty
- Control faulty
- Sewing motor rough-running
- Sewing motor faulty
- Control faulty
Sewing motor faulty
Failure
- Sewing motor blocked/
rough-running
- Sewing motor faulty
- Control faulty
- Cable to sewing motor
- Reference switch faulty
- Sewing motor faulty
- Mechanical parts
rough-running
- Plug for sewing motor
not plugged in
- Plug for incremental
sensor not plugged in
Internal error
- Cable to
reference switch faulty
- Reference switch faulty
- Step motor faulty
Mechanical part
rough-running
- Step motor X-Axis
faulty
- Control faulty
Mains voltage too high
Troubleshooting
- Check cable
- Check reference switch
Check sewing motor
- Check the mechanical parts
- Check sewing motor cable
- Check sewing motor
- Check control
- Check the serial number of the
1
DAC III control unit
, if necessary
load the correct software version.
Check the mains voltage
- Eliminate blocking/rough-running
- Check sewing motor
- Check control
- Eliminate rough-running
- Check sewing motor
- Check control
Check sewing motor
Switch the sewing machine off
and on again
-
Eliminate blocking/rough-running
- Check sewing motor
- Check control
- Check cable
- Check reference switch
Check sewing motor
- Check the mechanical parts
- Connect the plug for the sewing
motor
- Connect the plug for the
incremental sensor
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
- Check cable
- Check reference switch
- Check step motor
- Check the mechanical parts
- Check step motor X-Axis
- Check control
Check the mains voltage
1