Outputs
With this test function the function of the output elements is checked.
–
Start the test function with the "OK" key.
–
Select the desired output element with the keys "ñ " or "ò ".
–
Confirm the selected output element with the "OK" key.
–
Switch the output element with the keys "ï" or "ð ".
–
Press the function key "ESC" for quitting the test function.
Caution: Risk of injury !
Do not reach into the running machine during the function test of the
output elements.
Output
element
5
6
7
8
9
10 to 16
17
18
19
20
21
Function
Needle cooling
Clamp 2 open/ closed
Clamp 1 open/ closed
Lift/ lower the foot
Lamp "Safe stop"
Laser lamps
Lower / Lift the thread burner
Retract the upper thread burner
Thread wiper
Retract the lower thread burner
Thread burner heater on