Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller.
PCNTNW-NW-074 The hardware interrupt cannot be set.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the Link Support
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free Count.
PCNTNW-NW-086 The driver parameter block is too small.
PCNTNW-NW-087 The media parameter block is too small.
PCNTNW-NW-091 The hardware configuration conflicts.
PCNTNW-NW-126 The group bit in the node address override was cleared.
PCNTNW-NW-127 The local bit in the node address override was set.
PCNTNW-NW-164 The device was not found.
38
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
Explanation: An attempt was made to initialize a given hardware interrupt. The attempt was
not successful. Action: Verify that the Ethernet controller is enabled. If the Ethernet
controller is enabled, go to "Starting the diagnostic programs" on page 25 to run the
diagnostic programs.
If you have an Ethernet adapter installed, make sure that the adapter does not share an IRQ
with any other device.
Layer (LSL).
Explanation: An error occurred while the driver was trying to register with the LSL. Action:
Check the version of the NetWare or IntraNetWare Operating System. Make sure that this
driver is correct for the version of NetWare or IntraNetWare that you are using. Restart the
server.
Explanation: The MSMTx Free Count is not initialized correctly. Action: Restart the server. If
the problem persists, go to "Starting the diagnostic programs" on page 25 to run the
diagnostic programs.
Explanation: The driver parameter block is too small.Action: Restart the server. If the
problem persists, go to "Starting the diagnostic programs" on page 25 to run the diagnostic
programs.
Explanation: The driver media parameter block is too small.Action: Restart the server. If the
problem persists, go to "Starting the diagnostic programs" on page 25 to run the diagnostic
programs.
Explanation: You tried to load a new frame type for the existing controller. The hardware
assumptions made in doing so are incorrect. This error can also occur if you try to specify a
mode (such as, redundancy) that conflicts with another specified mode. Action: Make sure
that your hardware configuration matches the software settings.
Explanation: The IEEE address has a group bit that indicates that an address belongs to a
group of stations. This bit is used only as a destination address; it cannot be used as a source
address. You tried to enter a source address with this bit set. The driver cleared the group bit
of the source address. Action: None necessary, message is for information only.
Explanation: The local bit in the IEEE address format indicates that the addresses are being
managed locally. If you use the node address override capabilities of this driver to enter a
new address, the local bit must be set. You entered an address without the local bit set. The
driver has set the local bit. Action: None necessary, message is for information only.
Explanation: The driver cannot find an Ethernet controller in the server. Action: Verify that
the Ethernet controller is enabled. If the Ethernet controller is enabled, go to "Starting the
diagnostic programs" on page 25 to run the diagnostic programs.