IBM 86655RY - Netfinity 7600 - 8665 Hardware Maintenance Manual page 31

Models 1ry, 2ry
Table of Contents

Advertisement

BCS
ECS
07
08
07
0C
07
18
07
1C
07
28
07
2C
07
38
07
3C
07
48
07
4C
07
58
07
5C
07
68
Explanation and possible recovery action
Explanation: Online/rebuild drives are not responding.
Action: Press F4, F5, or F10.
Explanation: Online/rebuild drives are not responding, and a drive was found at
the incorrect SCSI ID.
Action: Press F4, F5, F6, or F10.
Explanation: Online/rebuild and hot-spare/standby hot-spare drives are not
responding.
Action: Press F4, F5, or F10.
Explanation: Online/rebuild and hot spare/standby hot-spare drives are not
responding, and a drive was found at the incorrect SCSI ID.
Action: Press F4, F5, F6, or F10.
Explanation: Online/rebuild and ready/standby drives are not responding.
Action: Press F4, F5, or F10.
Explanation: Online/rebuild and ready/standby drives are not responding, and a
drive was found at the incorrect SCSI ID.
Action: Press F4, F5, F6, or F10.
Explanation: Online/rebuild, ready/standby, and hot-spare/standby hot-spare
drives are not responding.
Action: Press F4, F5, or F10.
Explanation: Online/rebuild, ready/standby, and hot-spare/standby hot-spare
drives are not responding, and a drive was found at the incorrect SCSI ID.
Action: Press F4, F5, F6, or F10.
Explanation: Online/rebuild drives are not responding, and unidentified drives
were found.
Action: Press F4, F5, or F10.
Explanation: Online/rebuild drives are not responding, and a drive was found at
the incorrect SCSI ID, and unidentified drives were found.
Action: Press F4, F5, F6, or F10.
Explanation: Online/rebuild and hot spare/standby hot-spare drives are not
responding, and unidentified drives were found.
Action: Press F4, F5, or F10.
Explanation: Online/rebuild and hot spare/standby hot-spare drives are not
responding, a drive was found at the incorrect SCSI ID, and unidentified drives
were found.
Action: Press F4, F5, F6, or F10.
Explanation: Online/rebuild and ready/standby drives are not responding, and
unidentified drives were found.
Action: Press F4, F5, or F10.