Symptom-To-Fru Index; Beep Symptoms - IBM 86655RY - Netfinity 7600 - 8665 Hardware Maintenance Manual

Models 1ry, 2ry
Table of Contents

Advertisement

Symptom-to-FRU index

Beep symptoms

Beeps
1-2-3
4
Beep/Symptom
1-1-3
(CMOS write/read test
failed)
1-1-4 (BIOS EEPROM checksum
failed)
(Programmable Interval
1-2-1
Timer failed)
1-2-2(DMA initialization failed)
1-2-3(DMA page register write/read
failed)
© Copyright IBM Corp. 1999, 2000
This index supports Netfinity 7600 – Type 8665 servers.
Notes:
1.Check the configuration before you replace a FRU. Configuration problems can
cause false errors and symptoms.
2.The default configuration can be loaded by starting the system and then pressing
the reset button four times, waiting 15 seconds between each press. Once the
configuration has reset to the default, it must be saved in Setup to be stored in
CMOS.
3.For IBM devices not supported by index, refer to the manual for that device.
4.Always start with "Chapter . General checkout," on page 1.
The Symptom-to-FRU lists symptoms, errors, and the possible causes. The most
likely cause is listed first. Use this Symptom-to-FRU index to help you decide which
FRUs to have available when servicing the computer. The POST BIOS displays POST
error codes and messages on the screen.
Beep symptoms are short tones or a series of short tones separated by pauses
(intervals without sound). See the following examples.
Note: One beep after successfully completing POST indicates the system is
functioning properly.
One beep
A pause (or break)
Two beeps
A pause (or break)
Three Beeps
Four continuous beeps
1.
Battery
2.
I/O Legacy Board
1.
I/O Legacy Board
1.
I/O Legacy Board
1.
I/O Legacy Board
1.
I/O Legacy Board
Description
FRU/Action
215

Advertisement

Table of Contents
loading

This manual is also suitable for:

866561y - eserver xseries 250Netfinity 7600 8665

Table of Contents