IBM 86655RY - Netfinity 7600 - 8665 Hardware Maintenance Manual page 30

Models 1ry, 2ry
Table of Contents

Advertisement

BCS
ECS
01
58
01
68
01
78
03
88
03
98
03
A8
03
B8
03
C8
03
D8
03
E8
03
F8
20
Hardware Maintenance Manual: Netfinity 7600 – Type 8665 Models 1RY, 2RY
Explanation and possible recovery action
Explanation: No configuration was found in drives, or online/rebuild and hot-
spare/standby hot-spare drives are not responding and unidentified drives were
found.
Action: Press F4, F5, F7, or F10.
Explanation: No configuration was found in drives, or online/rebuild and
ready/standby drives are not responding and unidentified drives were found.
Action: Press F4, F5, F7, or F10.
Explanation: No configuration was found in drives, or online/rebuild, hot-
spare/standby hot-spare, and ready/standby drives are not responding and
unidentified drives were found.
Action: Press F4, F5, F7, or F10.
Explanation: A drive was imported from another system and it has valid
configuration, and online/rebuild drives are not responding.
Action: Press F4, F5, F7, or F10.
Explanation: A drive was imported from another system and it has valid
configuration, and online/rebuild and hot spare/standby hot-spare drives are not
responding.
Action: Press F4, F5, F7, or F10.
Explanation: A drive was imported from another system and it has valid
configuration, and online/rebuild and ready/standby drives are not responding.
Action: Press F4, F5, F7, or F10.
Explanation: A drive was imported from another system and it has valid
configuration, and online/rebuild, hot-spare/standby hot-spare, and
ready/standby drives are not responding.
Action: Press F4, F5, F7, or F10.
Explanation: A drive was imported from another system and it has valid
configuration, and online/rebuild drives are not responding and unidentified
drives were found.
Action: Press F4, F5, F7, or F10.
Explanation: A drive was imported from another system and it has valid
configuration, and online/rebuild and hot-spare/standby hot-spare drives are not
responding and unidentified drives were found.
Action: Press F4, F5, F7, or F10.
Explanation: A drive was imported from another system and it has valid
configuration, and online/rebuild and ready/standby drives are not responding
and unidentified drives were found.
Action: Press F4, F5, F7, or F10.
Explanation: A drive was imported from another system and it has valid
configuration, and online/rebuild, hot-spare/standby hot-spare, and
ready/standby drives are not responding and unidentified drives were found.
Action: Press F4, F5, F7, or F10.

Advertisement

Table of Contents
loading

This manual is also suitable for:

866561y - eserver xseries 250Netfinity 7600 8665