4.2
System Programming
Description
Selection
Default
Programming
Conditions
Feature Reference
Station Hunting Type
Used to set the Station Hunting type for each extension group.
There are two Station Hunting types available: Circular and
Terminating. If circular is assigned for a group, all of the extensions
in the group are searched one time until an idle one is found. If
terminating is assigned, searching stops at the extension which has
the highest jack number in the group.
• Extension group number: 1 – 8,
• Terminate (terminating) / Circular
All extension groups – Terminate
1.
Enter 101.
Display: Hunting Type
2.
Press NEXT.
Display: Group NO?
3.
Enter an extension group number.
Pressing NEXT also can enter extension group number 1.
Display example: Group1:Terminate
4.
Keep pressing SELECT until the desired selection is
displayed.
5.
Press STORE.
6.
To program another extension group, press NEXT or PREV,
or SELECT and enter the desired extension group number.
7.
Repeat steps 4 through 6.
8.
Press END.
• Program [600] "Extension Group Assignment" is used to assign the
extension group members.
• If all extensions are busy, a busy tone will be heard.
Section 3, Features
Station Hunting
(
= all extension groups)
System Programming
101