Triton T1/E1 Trunk Properties - Altigen AltiWare ACC 5.2 Administration Manual

Table of Contents

Advertisement

Triton T1/E1 Trunk Properties

To open a configuration dialog box for a Triton T1/E1 channel, do one of the following:
If you're in the Trunk Configuration window, select a Triton T1/E1 channel from
the trunk channels list, then click the Trunk Properties button, or just double-click
the channel in the list.
If you're in the Trunk View window, right-click the channel and select Channel
Properties.
Figure 6. Triton T1 Configuration dialog box
Following are the parameters for the Triton T1 Configuration dialog box:
Parameter
T1 robbed-bit signaling
Protocol
Dialing Delay
Description
You can set Protocol to one of the following:
E&M Wink Start (default)
E&M Immediate Start
Ground Start
• Loop Start
For signaling from one board to another, only E&M Wink
Start is supported. Loop Start, Ground Start, and E&M
Immediate Start protocols cannot be used for interfacing
between two boards.
Specifies the delay, in milliseconds, after trunk seizure and
before digit dialing. This configuration will slow down the
system transmitting digits to the CO by a defined delay to
avoid missing digits. Do not change this value unless advised.
AltiWare ACC 5.2 Administration Manual 145