hw-module power

To turn the power off on a slot or line module, use the no hw-module power command. To turn the power
back on, use the hw-module power command.
Syntax Description
slot
module
number
Defaults
After a boot up, the power is on.
Command Modes
Global configuration
Command History
Release
12.1(8a)EW
12.2(18)EW
Examples
This example shows how to shut off power to a module in slot 5:
Switch# no hw-module slot 5 power
Switch#
Related Commands
clear hw-module slot password
78-16201-01
hw-module [slot | module ] number power
no hw-module [slot | module ] number power
Modification
Support for this command was introduced on the Catalyst 4500 series switch.
Add slot and module keywords.
Catalyst4500 Series SwitchCiscoIOS Command Reference—Release 12.2(18)EW
(Optional) Specifies a slot on a chassis.
(Optional) Specifies a line module.
(Optional) Specifies the slot or module number.