PLC-XC50/55 Expand Serial Command Functional Specifications
Acceptable
Response
Unacceptable

9.11.21 CR_RCODE Command

Command
"CR_RCODE"[CR]
Details
Get selected Remote Control Code
Acceptable
Response
%a
Unacceptable

9.11.22 CR_KEYDIS Command

Command
"CR_KEYDIS"(CR)
Details
Get disability status of RC/Projector keys (valid or invalid)
Acceptable
Response
%a
Unacceptable

9.11.23 CR_SECURITY Command

Command
"CR_SECURITY" [CR]
Details
Get Security Mode setting status
Acceptable
Response
%1
Unacceptable

9.11.24 CR_PJLOCKNOW Command

Command
"CR_PJLOCKNOW" [CR]
Details
Get if PJ lock is actually in operation
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"09" = Remaining number of usable Filter scroll : 9 times
%1
"00" = Remaining number of usable Filter scroll : 0 time
"Error Code" [CR]
"000_%a"[CR]
"001" --------------------------- Code1 is selected
"002" --------------------------- Code2 is selected
"003" --------------------------- Code3 is selected
"004" --------------------------- Code4 is selected
"005" --------------------------- Code5 is selected
"006" --------------------------- Code6 is selected
"007" --------------------------- Code7 is selected
"008" --------------------------- Code8 is selected
"?"[CR]
"000_%a"[CR]
"NONE" -------------------------- RC / Projector keys are valid
"RC" ------------------------------ RC keys are invalid
"KEY" ----------------------------- Projector keys are invalid
"?"[CR]
"000_%1[CR]
"ON" ------------- PJ Lock setting on Menu is ON-1 or ON-2
"OFF" ------------PJ Lock setting on Menu is OFF
"Error Code" [CR]
"000_%1[CR]
"LOCK" ------------- PJ Lock is in operation. PJ Lock status is ON-1
or ON-2 on Menu, and PJ PIN CODE is not
entered so that projector is actually locked.
"FREE" ------------- PJ Lock is released. PJ Lock status is OFF, or,
status is ON-1 or ON-2 on Menu but PJ PIN
CODE is entered correctly so that PJ Lock is
released.
"Error Code" [CR]