Vsan Database - Cisco AJ732A - MDS 9134 Fabric Switch Command Reference Manual

Cisco mds 9000 family command reference guide - release 4.x (ol-18089-01, february 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 25
V Commands
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

vsan database

To create multiple fabrics sharing the same physical infrastructure, assign ports to VSANs, turn on or
off interop mode, load balance either per originator exchange or by source-destination ID, and enter
VSAN database submode, enable the load balancing guarantee for the selected VSAN and directs the
switch to use the source and destination ID for its path selection process, use the vsan database
command. To remove a configuration, use the no command in VSAN database submode.
On a Cisco Fabric Switch for HP c-Class BladeSystem and on a Cisco Fabric Switch for IBM
Note
BladeCenter, the syntax differs as follows:
interface bay port | ext port
Syntax Description
vsan vsan-id
interface fc slot/port
interface bay port | ext port (Optional) Specifies the Fibre Channel interface by port number on a
fcip fcip-id
fv slot/dpp-number/fv-port Configures the virtual F port (FV port) interface in the specified slot
iscsi slot/port
OL-18089-01, Cisco MDS NX-OS Release 4.x
vsan database
vsan vsan-id [interface fc slot/port | fcip fcip-id | fv slot/dpp-number/fv-port | iscsi slot/port |
port-channel portchannel-number.subinterface-number} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id} | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
vsan database
no vsan vsan-id [interface {fc slot/port | fcip fcip-id | fv slot/dpp-number/fv-port | iscsi
slot/port | port-channel portchannel-number.subinterface-number} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id} | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
Specifies the VSAN ID. The range is 1 to 4093.
(Optional) Specifies the Fibre Channel interface by slot and port number
on a Cisco MDS 9000 Family switch.
Cisco Fabric Switch for HP c-Class BladeSystem or on a Cisco Fabric
Switch for IBM BladeCenter. The range is 0 to 48.
(Optional) Specifies the FCIP interface on a Cisco MDS 9000 Family
switch.
along with the data path processor (DPP) number and the FV port
number.
(Optional) Configures the iSCSI interface in the specified slot/port on a
Cisco MDS 9000 Family switch.
Cisco MDS 9000 Family Command Reference
vsan database
25-9