Intel® Server System M20NTP1UR - System Integration and Service Guide
3.3
Power Supply Module Installation
To provide support for power redundancy, a second power supply can be added to the base system.
Required Tools and Supplies
Intel accessory kit: iPC AXXBFP750SLPS - 750W AC Slim-line power supply module
•
Anti-static wrist strap and conductive workbench pad (recommended)
•
1. (If present) Remove the insert from the power supply bay
2. Locate and unpack the new power supply module
3. Install power supply into the system (See
Slide the power supply into the power supply bay until it clicks and locks in place
•
Note: A single power supply configuration requires that the power supply bay insert be installed in the
unused bay when the system is operational.
3.4
PCIe* Add-in Card Installation
The Intel® Server System M20NTP1UR has support for up to two PCIe* add-in cards. This section provides
instructions for adding a PCIe* add-in card into a riser card.
Required Tools and Supplies
•
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver
•
1. Power off the system and disconnect all cables from the back of the system
2. Remove the system top cover (see
3. Remove the Air Duct (see
Figure
Figure 25. Power Supply Installation
Section
3.1.1).
Section
3.2.1)
25)
31