Juniper JUNOS OS 10.4 - RELEASE NOTES Release Note page 54

Table of Contents

Advertisement

JUNOS OS 10.4 Release Notes
54
On M Series and MX Series routers, after a hot-standby RMS, all existing flows are
dropped and it takes some time for new flows to appear with the state. This is due to
the limitation of the RMS. All existing traffic is dropped, and RPC is most impacted as
it has a long retry timer and takes a long time to recover. [PR/535597]
When unit 0 of the Multiservices PIC interface is not specified, the
traffic
command does not display the input packet's number properly for that particular
ms-I/F interface. [PR/544318]
On Multiservices 500 PICs with graceful Routing Engine switchover, wrong record
values are seen for the IPv4 netflow export packets. This error occurs when the route
records does not get installed. [PR/545422]
The MS400 PIC crashes due to a memory allocation failure when the PIC tries to
respond to a Routing Engine CLI request. [PR/558237]
User Interface and Configuration
In the J-Web interface , the "Generate Report" option under Monitor Event and Alarms
opens the report in the same web page. [PR/433883]
Selecting the monitor port for any port in the Chassis Viewer page displays the common
Port Monitoring page instead of the corresponding Monitoring page of the selected
port. [PR/446890]
On MX Series routers, J-Web does not display the USB-related information under
Monitor>SystemView>System Information>Storage. [PR/465147]
When a new-line character (\n) is used within the op script argument descriptions, the
help output might display incorrectly, and could result in extra output being displayed
when the op script executes. [PR/485253]
In the J-Web interface, the options
for PPPoE logical interfaces are not supported on MX Series routers. [PR/493451]
The J-Web interface does not display the drop-profile-map, excess-priority, excess-rate,
and rate-limit (transmit rate) parameters which are supported for the schedulers
configuration. Use these parameters using the CLI. [PR/495947]
Warning messages related to pending commits are not triggered when the following
operations are performed:
Software->Upload
Software->Install Package
Maintain->Reboot
As a workaround, commit all pending commits before performing the operations listed
above. [PR/514853]
The
option does not appear when it is used with the
annotate
for class of service. [PR/535574]
When a HTTPS connection is used for the J-Web interface in the Internet Explorer to
save a report from the View Events page (Monitor->Events and Alarms->View events),
,
Access Concentrator
Idle Timeout
Copyright © 2010, Juniper Networks, Inc.
monitor interface
, and
Service Name
command