Prior to a power on RESET# and during RESET# assertion, PECI is not guaranteed to
provide reliable thermal data. System designs should implement a default power-on
condition that ensures proper processor operation during the time frame when reliable
data is not available via PECI.
To protect platforms from potential operational or safety issues due to an abnormal
condition on PECI, the Host controller should take action to protect the system from
possible damaging states. If the Host controller cannot complete a valid PECI
transactions of GetTemp0() with a given PECI device over 3 consecutive failed
transactions or a one second max specified interval, then it should take appropriate
actions to protect the corresponding device and/or other system components from
overheating. The host controller may also implement an alert to software in the event
of a critical or continuous fault condition.
6.3.2.3
PECI GetTemp0() and GetTemp1() Error Code Support
The error codes supported for the processor GetTemp0() and GetTemp1() commands
are listed in
Table 6-11. GetTemp0() and GetTemp1() Error Codes
Error Code
0x8000
0x8002
110
Table 6-11
below:
General sensor error
Sensor is operational, but has detected a temperature below its operational range
(underflow), currently 30
Description
o
C absolute temperature.
§
Thermal Specifications