ZyXEL Communications ZYWALL 35 User Manual page 753

Internet security appliance
Hide thumbs Also See for ZYWALL 35:
Table of Contents

Advertisement

• If there is a DHCP server on your network, make sure your computer is using a
dynamic IP address. See
by default.
6 Reset the device to its factory defaults, and try to access the ZyWALL with the default
IP address. See
7 If the problem continues, contact the network administrator or vendor, or try one of the
advanced suggestions.
Advanced Suggestions
• Try to access the ZyWALL using another service, such as Telnet. If you can access the
ZyWALL, check the remote management settings, firewall rules, and SMT filters to find
out why the ZyWALL does not respond to HTTP.
• If your computer is connected to the WAN port or is connected wirelessly, use a computer
that is connected to a LAN port.
• You may also need to clear your Internet browser's cache.
In Internet Explorer, click Tools and then Internet Options to open the Internet Options
screen.
In the General tab, click Delete Files. In the pop-up window, select the Delete all offline
content check box and click OK. Click OK in the Internet Options screen to close it.
• If you disconnect your computer from one device and connect it to another device that has
the same IP address, your computer's ARP (Address Resolution Protocol) table may
contain an entry that maps the management IP address to the previous device's MAC
address).
In Windows, use arp -d at the command prompt to delete all entries in your computer's
ARP table.
I can see the Login screen, but I cannot log in to the ZyWALL.
1 Make sure you have entered the user name and password correctly. The default user
name is admin, and the default password is 1234. These fields are case-sensitive, so
make sure [Caps Lock] is not on.
2 You cannot log in to the web configurator while someone is using the SMT, Telnet, or
the console port to access the ZyWALL. Log out of the ZyWALL in the other session, or
ask the person who is logged in to log out.
3 Turn the ZyWALL off and on or disconnect and re-connect the power adaptor or cord to
the ZyWALL.
4 If this does not work, you have to reset the device to its factory defaults. See
on page
I cannot access the SMT. / I cannot Telnet to the ZyWALL.
ZyWALL 5/35/70 Series User's Guide
Appendix D on page
Section 2.3 on page
63.
Chapter 53 Troubleshooting
781. Your ZyWALL is a DHCP server
63.
Section 2.3
753

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents