Configuring Idp Signatures; Figure 162 Security > Idp > Signature: Actions; Figure 163 Security > Idp > Signature: Group View; Table 80 Security > Idp > Signature: Actions - ZyXEL Communications ZYWALL 35 User Manual

Internet security appliance
Hide thumbs Also See for ZYWALL 35:
Table of Contents

Advertisement

Chapter 13 Configuring IDP
Figure 162 SECURITY > IDP > Signature: Actions
The following table describes signature actions.
Table 80 SECURITY > IDP > Signature: Actions
ACTION
No Action
Drop Packet
Drop Session
Reset Sender
Reset Receiver
Reset Both

13.3.4 Configuring IDP Signatures

Click IDP > Signature to see the ZyWALL's "group view" signature screen where you can
view signatures by attack type. To search for signatures based on other criteria such as
signature name or ID, then click the Switch to query view link to go to the "query view"
screen.
You can take actions on these signatures as described in
to the default actions or to save sets of actions, go to the Backup & Restore screen.
Figure 163 SECURITY > IDP > Signature: Group View
284
DESCRIPTION
The intrusion is detected but no action is taken.
The packet is silently discarded.
When the firewall is enabled, subsequent TCP/IP packets belonging to the
same connection are dropped. Neither sender nor receiver are sent TCP RST
packets. If the firewall is not enabled only the packet that matched the
signature is dropped.
When the firewall is enabled, the TCP/IP connection is silently torn down. Just
the sender is sent TCP RST packets. If the firewall is not enabled only the
packet that matched the signature is dropped.
When the firewall is enabled, the TCP/IP connection is silently torn down. Just
the receiver is sent TCP RST packets. If the firewall is not enabled only the
packet that matched the signature is dropped.
When the firewall is enabled, the TCP/IP connection is silently torn down. Both
sender and receiver are sent TCP RST packets. If the firewall is not enabled
only the packet that matched the signature is dropped.