rewiring to 440v

the Model g0451 can be rewired for 440v opera-
tion. the necessary parts for this procedure can
be purchased by calling our customer service at
(800) 523-4777 and ordering part #p04510016.
this rewiring job must be inspected by a quali-
fied electrician before the saw is connected to the
power source. Also, the motors can be accessed
easier for rewiring if the blade is moved to 0˚ (90˚
to table) before beginning.
To rewire the machine for 440v operation:
1.
disConneCt sAW FroM poWer!
2.
open the electrical panel and locate the volt-
age transformer shown in figure 9.
electrical
Access panel
Main Motor
overload relay
scoring Motor
overload relay
figure 9. inside view of the control panel.
3.
pull the fuse that is in the "220" slot and push
it into the "440" slot (see figure 10).
figure 10. Fuse installed at the 220v location.
g0451 14" sliding table saw
voltage
transformer
Fuse
4.
remove the main motor overload relay
(figure 11) and replace it with the overload
relay from the 440v conversion kit. turn the
dial on the main motor overload relay to 9A.
Main Motor
overload relay
figure 11. Motor overload relays.
5.
on the scoring motor overload relay, change
the dial setting to 2.6A.
6.
open the motor cabinet door and remove the
motor wiring covers from the main motor and
the scoring motor (see figure 12).
scoring
Motor
figure 12. Motor locations.
7.
rewire the motors as shown on the diagrams
that are placed on the inside of the motor wir-
ing covers.
scoring Motor
overload relay
Main
Motor
-17-