Test Run - Grizzly G0451 Instruction Manual

14" sliding table saw
Hide thumbs Also See for G0451:
Table of Contents

Advertisement

Test run

After the machine has been connected to the
power source, the machine Must be test run to
make sure all the controls are working properly.
the test run includes verifying that the safety
disabling components on the machine work cor-
rectly.
Before beginning the test run, review the controls
shown in figures 56 & 57.
Blade on Buttons
power switch
power light
Blade oFF Buttons
figure 56. Main power controls.
#2 emergency stop switch
figure 57. emergency stop switch #2.
g0451 14" sliding table saw
#1 emergency
stop switch
if the machine does not operate as stated
in this section, review the troubleshooting
section in this manual. if you need addi-
tional help, call Tech Support at (570) 546-
9663. dO nOT place a machine into regular
operation if you suspect that it is malfunc-
tioning or serious injury could occur.
To test run the saw:
1.
put on safety glasses, make sure any
bystanders are out of the way, and that all
tools have been removed from the saw.
2.
insert the key into the power switch and turn
it clockwise.
3.
push in, then rotate both emergency stop
switches clockwise until they pop out. this
resets the emergency stop switches so the
machine can operate.
4.
one at a time, press the blade on buttons.
the blades should startup and run smoothly
without any problems.
—if any problems occur, press the nearest
emergency stop switch.
5.
one at a time, press the blade oFF buttons.
the blades should stop running. As the main
blade comes to a stop, watch the direction
that it is spinning.
—if the main blade is rotating counterclock-
wise, disconnect the saw from power and
exchange wires r & t in the power con-
nection box.
6.
depress the #1 emergency stop switch.
-33-

Advertisement

Table of Contents
loading

Table of Contents