Second motor selection

This function switches between two motors for one Inverter. V/f control
must be used for the second motor. Switching is possible from a multi-
function input.
The following constants are used as control constants for motor 2.
Con-
Name
stant
No.
Control Mode Selec-
tion
n140
Motor 2 Maximum Out-
put Frequency
n158
Motor 2 Maximum
Voltage
n147
Motor 2 Maximum
Voltage Output Fre-
quency
n159
Motor 2 Middle Output
Frequency Voltage
n014
Middle Output
Frequency
n160
Motor 2 Minimum Out-
put Frequency Voltage
n161
Motor 2 Rated Current
n162
Motor 2 Rated Slip
Note: Not initialized when constants are initialized.
* 1. Upper limit of setting range and factory setting are doubled for 400-V
Class Inverters.
* 2. Depends on Inverter capacity.
6 Programming Features
Unit
Setting Range
V/f control must be
0.1 Hz
50.0 to 400.0 Hz
0.1 V
0.1 to 255.0 V
0.1 Hz
0.2 to 400.0 Hz
0.1 V
0.1 to 255.0 V
0.1 Hz
0.1 to 399.9 Hz
0.1 V
0.1 to 50.0 V
0.1 A
0.0 to 150% of
Inverter rated cur-
0.1 Hz
0.0 to 20.0 Hz
Factory
Setting
used.
50.0 Hz
200.0 V
*1
*1
50.0 Hz
12.0 V
*1
*1*2
1.3 Hz
12.0 V
*1
*1*2
*2
rent
*2
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents