Omron VARISPEED V7 User Manual page 93

Varispeed v7 compact sensorless vector inverter
Hide thumbs Also See for VARISPEED V7:
Table of Contents

Advertisement

n065 Setting
n065 Setting
0
1
Pulse train signal can be selected by setting in n150.
n150 Setting
0
1
6
12
24
36
40
41
42
43
44
45
50
Note: Enabled only when n065 is set to 1 (pulse monitor output).
92
Description
Analog monitor output
Pulse monitor output
(Output frequency monitor)
Output
frequency
monitor
Frequency
reference
monitor
Data Output
via Communi-
cations
Description
1440 Hz/Max. frequency (n011)
1F: Output frequency × 1
6F: Output frequency × 6
12F: Output frequency × 12
24F: Output frequency × 24
36F: Output frequency × 36
1440 Hz/Max. frequency (n011)
1F: Output frequency × 1
6F: Output frequency × 6
12F: Output frequency × 12
24F: Output frequency × 24
36F: Output frequency × 36
0 to 14,400 Hz output (MEMO-
BUS register No.000AH) (1 Hz/
1)

Hide quick links: