Omron VARISPEED V7 User Manual page 41

Varispeed v7 compact sensorless vector inverter
Hide thumbs Also See for VARISPEED V7:
Table of Contents

Advertisement

Operation Steps
1. Turn ON the power supply.
2. Set constant n004 to 1.
3. Set the following constants.
n019: 15.0 (acceleration time)
n020: 5.0 (deceleration time)
4. Select forward or reverse run by press-
ing
or
Never select REV when reverse
run is prohibited.
NOTE
5. Set the reference by pressing
key.
6. Press
.
7. Press
If the potentiometer is switched
rapidly, the motor also acceler-
NOTE
ates or decelerates rapidly in
proportion to the potentiometer
movement. Pay attention to load
status and switch the potentiom-
eter at the speed that will not
adversely affect motor move-
ment.
Status indicators
40
key.
to stop.
: ON
: Flashing (Long flashing)
Operator
Display
6.00
1
15.0
5.0
(Forward)
or
(Reverse)
60.00
or
0.00→60.00
60.00→0.00
Function
Status
Indicators
Indicators
FREF
RUN
ALARM
PRGM
RUN
ALARM
PRGM
RUN
ALARM
F/R
RUN
ALARM
RUN
FREF
ALARM
FOUT
RUN
ALARM
FOUT
RUN
ALARM
: Flashing
: OFF