Omron VARISPEED V7 User Manual page 151

Varispeed v7 compact sensorless vector inverter
Hide thumbs Also See for VARISPEED V7:
Table of Contents

Advertisement

• Simultaneous Broadcasting Data (available only for write in)
Register
Bit
No.
0001H
6-F
Frequency reference 30000/100 % fixed unit
0002H
(Data is converted into 0.01 Hz inside the Inverter, and fractions
are rounded off.)
Bit signals not defined as the broadcast operation signals are used as
the local station data signals.
• Monitor Data (available only for read out)
Register
No.
0020H
150
0
Run Command
1
Reverse Run Command 1: Reverse run 0: Forward run
2
(Not used)
3
(Not used)
4
External fault
5
Fault Reset Command
(Not used)
Bit
0
Run Command
1
Reverse Run Command 1: Reverse run 0: Forward run
2
Inverter operation ready 1: Ready
3
Fault
4
Data setting error
5
Multi-function output 1
6
Multi-function output 2
7
Multi-function output 3
8-F
(Not used)
Description
1: Run
1: Fault (EFO)
1: Fault Reset
Description
1: Run
1: Fault
1: Error
(1: MA ON
(1: P1 ON
(1: P2 ON
0: Stop
0: Stop
0: Not ready
0: MA OFF)
0: P1 OFF)
0: P2 OFF)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents