Voltage Class
Model
3-phase
CIMR-
V7AZ
Single-phase
Control Method
Frequency Control
Range
Frequency Accuracy
(Temperature Change)
Frequency Setting
Resolution
Output Frequency
Resolution
Overload Capacity
Frequency Reference
Signal
Acceleration/Decelera-
tion Time
Braking Torque
V/f Characteristics
Motor Overload
Protection
Instantaneous Over-
current
Overload
Overvoltage
Undervoltage
Momentary Power
Loss
Heatsink Overheat
Stall Prevention Level
Cooling Fan Fault
*4
Ground Fault
Power Charge
Indication
40P2
40P4
40P7
-
-
-
Sine wave PWM (V/f control/vector control selectable)
0.1 to 400 Hz
Digital reference: ±0.01 %, −10 to 50 °C (14 to 122 °F)
Analog reference: ±0.5 %, 25±10 °C (59 to 95 °F)
Digital reference:
0.01 Hz (less than 100 Hz)/0.1 Hz (100 Hz or more)
Analog reference: 1/1000 of max. output frequency
0.01 Hz
150% rated output current for one minute
0 to 10 VDC (20 kΩ), 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) pulse train
input, frequency setting potentiometer (Selectable)
0.00 to 6000 s
(Acceleration/deceleration time are independently programmed.)
Short-term average deceleration torque
0.2 kW: 150% or more
0.75 kW: 100% or more
1.5 kW (2 HP): 50% or more
2.2 kW (3 HP) or more: 20% or more
Continuous regenerative torque: Approx. 20% (150% with optional brak-
ing resistor, braking transistor built-in)
Possible to program any V/f pattern
Electronic thermal overload relay
Motor coasts to a stop at approx. 250% or more of Inverter rated current
Motor coasts to a stop after 1 minute at 150% of Inverter rated output cur-
rent
Motor coasts to a stop if DC bus voltage exceeds 820 V
Stops when DC bus voltage is approx. 400 V or less
The following items are selectable: Not provided (stops if power loss is 15
ms or longer), continuous operation if power loss is approx. 0.5 s or short-
er, continuous operation.
Protected by electronic circuit.
Can be set to individual levels during acceleration/constant-speed opera-
tion, provided/not provided available during deceleration.
Protected by electronic circuit (fan lock detection).
Protected by electronic circuit (overcurrent level).
ON until the DC bus voltage becomes 50 V or less. Charge LED is pro-
vided.
9 Specifications
400 V 3-phase
41P5
42P2
43P0
-
-
-
*2
44P0
45P5
47P5
-
-
-
*3