Switching Local/Remote Mode - Omron V7-IP65 User Manual

Compact sensorless vector inverter
Hide thumbs Also See for V7-IP65:
Table of Contents

Advertisement

When operating with a frequency larger than 60/50 Hz, change only the
Max. Output Frequency (n011).
n012
=200 V

Switching LOCAL/REMOTE Mode

The following functions can be selected by switching LOCAL or
REMOTE mode. To select the Run/Stop Command or frequency refer-
ence, change the mode in advance depending on the following applica-
tions.
• LOCAL mode: Enables the Digital Operator for Run/Stop Com-
• REMOTE mode: Enables Run Command Selection (n003).
Constant output or
Constant torque
variable output
Base point
n013
=60 or 50 Hz
mands and FWD/REV Run Commands. The fre-
quency reference can be set by using the
or
key.
The frequency reference can be set using the Fre-
quency Reference Selection (n004).
6 Programming Features
n011
=90 Hz
57