Switching Local/Remote Modes - Omron VS mini J7 User Manual

Compact general purpose inverter
Hide thumbs Also See for VS mini J7:
Table of Contents

Advertisement

Switching LOCAL/REMOTE Modes

The following functions can be selected by switching the LOCAL or
REMOTE mode. To select RUN/STOP commands or frequency
reference, change the mode in advance depending on the following
applications.
• LOCAL mode : Enables the digital operator for RUN/STOP
• REMOTE mode : Run by the n02 setting (run command selection).
How to select LOCAL/REMOTE modes
When LOCAL/REMOTE
switching function is not set
for multi-function input
selection
Select Lo for operator
selection.
LO/RE
LOCAL mode
40
commands and FWD/REV run commands.
Frequency reference can be set by volume or
Frequency reference can be set by n03 (frequency
reference selection) setting.
(When 17 is not set
to any of constants
n36 to n39)
Select rE for operator
selection.
LO/RE
When LOCAL/REMOTE
switching function is set at
multi-function input selection
Set
multi-function
input terminal is turned
ON.
REMOTE mode
.
FREF
(When 17 is set to
any of constants
n36 to n39)
Set
multi-function
input terminal is turned
OFF.

Advertisement

Table of Contents
loading