Code
Type
W
Printer Error
Wrong Length
Check
Mode
P,U, X
COMM
1
COMM
1
COMM
1
Causes
• Invalid printer format character
or invalid format sequence is used.
Link to invalid program number.
• Missing skip stop or tab stop in
program A.
• Printer format control crossed rec-
ord boundary.
• Format character R is used in print
current program.
Records received have inconsistent
or invalid record lengths.
• The number of characters in the
received data is not equal to the
number of greater than signs
(>)
in the receive data and insert con-
stants program.
• A continued data set on disk 2 has
a different record length from the
data set on disk 1.
1
COMM identifies errors that occur during communications; see
Communications.
What You Do
Reset, correct the printer format pro-
gram. See the
IBM 3741 Data Station
Reference Manual,
GA21-9183, for in-
formation on printer format programs.
If you have a 3715 Printer, see
Printer
Error Conditions.
The remote location has the problem.
After they correct it, re-establish the
connection.
Correct the receive data and insert con-
stants program. Restart communications.
Make sure that disk 2 contains the cor-
rect data set. Restart communications.