10 Setting Up IO-Link Devices
The IODDs that you added are displayed on the Installed IODDs tab page.
Precautions for Correct Use
You cannot use the IODD DTM Configurator to add or delete individually the IODD files with the
same vendor ID, device ID, and IO-Link revision, but different file version.
Perform the following operations to delete the OMRON IODD files that are already installed.
• To add IODD files
When you add the IODD files with the same vendor ID, device ID, and IO-Link revision, but
different file version, IODD files with the installed file version are overwritten.
• To delete IODD files
If several IODD files with the same vendor ID, device ID, and IO-Link revision, but different
file version are installed, when you delete individually the relevant IODD files, all of IODD files
differ from IODD files with the installed file version are deleted.
When you made a mistake and deleted different files, select OMRON IOLink IODD Files Setup
from Control Panel – Programs and Features, right-click the OMRON IOLink IODD Files Set-
up and execute Repair, the deleted files can be recovered.
Additional Information
• A set of OMRON IODD files is installed when you install the CX-ConfiguratorFDT.
• You can install IODD files from other companies. The operation differs depending on the ver-
sion as follows.
a) For the CX-ConfiguratorFDT version lower than 3.0, click the Install Device Description
Files button in the device catalog.
b) For the CX-ConfiguratorFDT version 3.0 or higher, click Install Device Description Files
or IODD Finder from the Profile Installation tab page of the Device or Topology ribbon.
10-2-5

Starting the CX-ConfiguratorFDT

Use one of the following methods to start the CX-ConfiguratorFDT. Examples of the starting methods
for the Windows 10 operation system are given below.
• If the Sysmac Studio is installed
Select OMRON – Sysmac Studio – CX-ConfiguratorFDT from the Windows Start menu.
• If the CX-One is installed
Select OMRON – CX-One – CX-ConfiguratorFDT from the Windows Start menu.
The first time you start the CX-ConfiguratorFDT, a dialog box to update the catalog is displayed auto-
matically.
Precautions for Correct Use
• Before you store (download) the settings to IO-Link devices, confirm that the controlled sys-
tem will not be adversely affected.
• You must update the device catalog after you install the CX-ConfiguratorFDT or after you in-
stall new DTMs.
• If DTM reading fails after you update the CX-One or restart the CX-ConfiguratorFDT applica-
tion, update the device catalog.
• You cannot read and write the "Process data values Output (from PLC)" value, which is dis-
played for Process data under Menu in the Configuration tab page for the IO-Link device. An
error is not displayed even if you perform one of the following operations for those values.
- Reading from device (Upload) or writing to device (Download)
- Enabling cycle read from device for process data
- Reading comparison values from device or writing different values to device
10-6
NXR-series IO-Link Master Unit for EtherCAT User's Manual (W640)