241
Impressed Current Anode: Open Circuit
314
ON / OFF repeated
321
Corrupted data
331
Missing communication between Main Board and HMI
332
333
Mainboard – WiFi board missing communication
Missing Communication between Inverter and main
334
board
335
Safety board communication failure
336
Touch screen not working
337
Cascade master missing
42 / EN
Check the presence of water inside the product.
If the error persists, verify the anode proper functioning. Check the cor-
OFF
OFF
rect assembly of anode wiring on related mainboard connector.
If the error persists, replace mainboard.
OFF
OFF Wait 15 minutes before unlocking the product with ON/OFF button
Reset the product by pressing the ON / OFF button twice.
OFF
OFF
If the error persists, replace the motherboard.
Reset the product by pushing the ON/OFF button twice. If the error persists,
OFF
OFF
replace the mainboard-display communication wiring.
If WiFi present:
- Check cables between motherboard and HMI.
- If the error persists, replace the HMI module.
ON
ON
If WiFi not present:
- Enter to the Installer Menu and set P31 OFF.
- If the error occurs again, replace the Main Board.
Check the communication cable and the related motherboard and TDC
ON
OFF
cables.
If the error persists, replace the TDC.
Reset the product by pressing the ON / OFF button twice.
OFF
OFF
If the error persists, replace the motherboard.
Reset the product by pressing the ON / OFF button twice.
ON
ON
If the error persists, replace the HMI.
Check that at least one of the products in the cascade is set as Master,
OFF
OFF
otherwise set one.