Installing The Appliance; Transport And Handling; Requirements For The Installation Site - Ariston 801 Instructions For Installation, Use, Maintenance

Heat pump water heater
Table of Contents

Advertisement

Available languages

Available languages

INSTALLING THE APPLIANCE

WARNING!
The installation and initial start-up of the appliance must be
performed by qualified personnel in compliance with the
national regulations in force regarding installation, and in
conformity with any regulations issued by local authorities
and public health bodies.
The installer is required to observe the instructions outlined
in this manual.
Once installation is complete, it is the installer's duty to in-
form and instruct the user on how to operate the water heat-
er and carry out the main operations correctly.

TRANSPORT AND HANDLING

Upon delivery of the product, check that the latter has not been
damaged during transport and that no signs of damage appear
on the packaging. In the event of damages, immediately notify
any claims to the forwarder.
WARNING!
THE APPLIANCE SHOULD BE HANDLED AND STORED IN A VER-
TICAL POSITION.
The product may be handled in a horizontal position only for short
distances, while resting on the rear end indicated; in this case, wait
at least 3 hours before starting the appliance once it has been cor-
rectly repositioned in a vertical position and/or installed; this is to
ensure that the lubricating oil inside the refrigeration circuit is suit-
ably distributed and to avoid damages to the compressor.
The packaged appliance may be handled while ensuring that
the above indications are observed. It is advisable to keep the
appliance in its original packaging until installing it in its chosen
location, particularly when construction work is under way on-site.
When transporting or handling the appliance after the initial in-
stallation, observe the aforementioned indication concerning the
allowed tilt angle and ensure that all water has been drained from
the tank.
Should the original packaging be missing, provide an adequate
protection for the appliance to prevent any damages, for which
the manufacturer shall not be held liable
ATTENTION! The packaging elements must not be left within the
reach of children, as they are sources of danger.
32 / EN
OK
NOT OK
WARNING!
The water heater is supplied with a sufficient amount of R290
refrigerant (propane) for its operation.
It is a flammable and odourless refrigerant with excellent
thermodynamic properties that produce a high level of energy
efficiency. Owing to its flammability, we recommend strictly
complying with the safety instructions given in this manual.
Never use equipment other than that recommended to speed up
defrosting or for cleaning purposes.
For repairs, strictly observe the manufacturer's instructions only
and always contact an authorised Technical Assistance Centre.
Any repairs carried out by unqualified personnel could be
dangerous.
The appliance must be installed in a place without ignition sources
operating continuously (for example: open flames, an operating
gas-fired device or an operating electric heater). Do not perforate
or burn the unit.
The appliance contains flammable R290 refrigerant. Warning:
refrigerants are odourless.

REQUIREMENTS FOR THE INSTALLATION SITE

WARNING! Prior to starting any installation activities, ensure that
the location where the water heater is to be installed satisfies the
following requirements:
DO NOT INSTALL THE WATER HEATER NEAR APPLIANCES
THAT GENERATE HEAT OR NEAR DANGEROUS AND/OR
FLAMMABLE MATERIALS.
a) If the appliance is installed without ducting, ensure that the
volume of the room where it is to be installed is not less than 20
m³, with adequate ventilation. Do not install the product in a room
containing an appliance that requires air to function (e.g. an open-
chamber gas boiler, an open-chamber gas water heater, etc.). Do
not install the product in a place where the noise produced and
the air expelled can be a source of inconvenience;
b) Check that from the place chosen for installation it is possible to
reach the outside with air ducting pipes (located in the upper part
of the product) PLEASE NOTE: the ducting pipes connected to
the appliance must be free of potential ignition sources;
c) Identify a suitable position on the wall, leaving enough space for
easily performing any maintenance interventions;
OUT
IN
MIN 300

Advertisement

Table of Contents
loading

This manual is also suitable for:

11011501

Table of Contents