VM-3100 List of Algoriyhms
bis
4 stage
Freq.
Level
Bs tage
Freq.
CenterFreq [Freq] (Center frequency)0 - 100
'This sets the center frequency of the phaser effect applied.
The phaser effect frequency range rises as the value is
increased.
Resonance [Reso]O - 100
The more this value is increased, the stronger this distinctive
effect becomes. However, setting the Resonance value too
high can result in extreme oscillation. Take care to prevent
this sound from damaging your ears or your playback
equipment.
LFO1 Depth [L1Dep]O - 100
LFO2 Depth [L2Dep]O - 100
These set the depth of the swelling sound.
LFO! Rate [L1Rat]O - 100
LFO2 Rate [L2Rat]O - 100
These set the modulation rate.
LFO1 Phase [L1Phs]NORM, INV
LFO2 Phase [L2Phs]NORM, INV
These set the phase of the modulation left and right. When
set to Normal (NORM), the phase is unchanged; when
inverted (INV), the phase is inverted.
wore
This algorithm reproduces the sound of the 2U rack-mounted
phasers of the early 1980s. Two monaural single-input, single-
output phasers are arranged in parallel, allowing the creation of
complex modulation patterns. The LFO1 and LFO2 have different
modulation rates. LFO1 creates an extremely slow modulation;
that of LFO2 is faster. You can set the phase of each one
independently. With a large swelling sound from LFO1 and a very
short, phase inverted wavering from in LFO2, you can create a
sound producing a sensation of great breadth.
21 HUM CANCELER
This removes unpleasant hum from the sound. Noise
suppression is added to the output.
Hum
Noise
Canceler
Suppressor
A >|
||
Le
HmcC
NS
B >|
Lom
je
HUM CANCELER
Frequency [Freq]20.0 - 800.0 Hz
This sets the frequency at which the hum is removed. Hum is
removed at the selected frequency as well as multiples of that
frequency. Set this to the frequency of your power source.
Width [Width] (Band Width)10 - 40 %
This sets the bandwidth of the filter removing the hum.
Depth [Depth]0 - 100
This sets the depth of the filter removing the hum.
Threshold [Thre] (Threshold Level)O - 100
This sets the level at which the Hum Canceller becomes
effective. When the signal falls below the specified level, only
the hum is removed the signal. At the maximum value, the
hum is removed at all times, regardless of the signal level.
Lo-F Limit [LoLim] (Low Frequency Limit)
THRU, 20 - 2000 Hz
This sets the minimum frequency for the Hum Canceller
function. When "THRU"
is selected, all frequencies that can
be played back through the A-6 are processed with the Hum
Canceller.
Hi-F Limit [HiLim] (High Frequency Limit)
1.0 = 20.0 kHz, THRU
This sets the maximum frequency for the Hum Canceller
function. When "THRU" is selected, all frequencies that can
be played back through the A-6 are processed with the Hum
Canceller.
NOISE SUPPRESSOR
These parameters function the same way as those in the
NOISE SUPPRESSOR in Algorithm 03 (VOCAL MULT)
(p.13).
Threshold [Thre] (Threshold Level)0 — 100
Release [Rele] (Release Time)0 ~ 100
22 CENTER CANCELER
Center Canceller is an effect that cuts out the sounds
positioned in the center of the stereo field. In addition to this,