Sensor Test
Use this test to determine if the input tray sensors are working correctly.
1
From the Diagnostics menu, navigate to:
Input Tray Tests > Sensor Test
2
Select the input source. All installed sources appear.
Not all sensors appear for all trays. The following table indicates which tray sensors are available for each
input source:
Input source
Standard tray
Optional 250‑/550-sheet tray
Multipurpose feeder
3
Manually actuate each sensor. The tray empty sensor can be actuated by hand; however, a sheet of paper
can be used to cover the pass through sensor.
4
Press X to exit the test.

OUTPUT BIN TESTS

Feed Tests
This test verifies that media can be fed to a specific output bin. No information is printed on the media.
To run this test:
1
From the Diagnostics menu, navigate to:
Output Bin Tests > Feed Tests
2
Select the output bin into which you want the paper to exit. All installed output bins appear.
3
Select one of the following:
Single—Feeds a single page.
Continuous—Continuously feeds pages until X is pressed.
Sensor Test
This test verifies that the output bin sensors are working correctly.
To run this test:
1
From the Diagnostics menu, navigate to:
Output Bin Tests > Sensor Test > Standard Bin
Testing... appears while the printer is verifying the state of the sensor.
The control panel displays the current state of the sensor.
Manually actuate the sensor to make it toggle between empty and full. If the sensor does not toggle,
2
then the sensor is malfunctioning.
Tray empty sensor Pass through sensor