Maintenance; Water Treatment System; Scale Related Maintenance; Draining Generator - Vulcan-Hart ML-138085 Installation & Operation Manual

Gas convection steamers
Table of Contents

Advertisement

Available languages

Available languages

C24GA SERIES GAS CONVECTION STEAMERS
The steamer and its parts are
hot. Use care when operating, cleaning or
servicing the steamer.

Water Treatment System

A water treatment system is recommended for
steamers. Refer to your supplier's manual for
normal maintenance procedures for proper
scale-free operation recommendations.

Scale Related Maintenance

Periodic maintenance is necessary to keep your
generator clean and efficient. Initially, after three
months of steamer usage, it is recommended
that you have your Vulcan authorized service
inspect the generator. Local water conditions
and steamer usage will determine the frequency
that this service must be repeated; however, a
minimum recommendation is once a year. This
maintenance is not covered by warranty.

MAINTENANCE

Draining Generator

At least once daily, turn the unit off with the
power switch located on bottom cooking cavity,
to drain the generator
Note: DO NOT remove the electric supply or
the unit will not drain.
Door Gaskets
If the door gasket is leaking due to a nick or
cut, it must be replaced. Damage to the gasket
sealing surface will cause steam leakage.

Flue

Annually (at minimum), when the steamer is
cool, check the flue and clear any obstructions.
— 16 —

Advertisement

Table of Contents
loading

This manual is also suitable for:

C24ga6C24ga10Ml-136056C24ga seriesMl-136057Ml-138086

Table of Contents