Thermal Overload Protection Reset Button; Maintenance; Flue Vent Inspection; Service In The Us And Canada - Vulcan-Hart VFRY Series Installation And Operational Manual

Gas fryers with kleenscreen plus filtration systems
Table of Contents

Advertisement

Available languages

Available languages

VK / TR / VFRY SERIES GAS FRYERS
THERMAL OVERLOAD PROTECTION BUTTON:
The motor/pump supplied with the
filtering system has a thermal
overload protection circuit that
senses when excess heat occurs.
This can occur due to filtering for
long periods of time or under heavy
load prior to discarding debris
buildup. If the thermal overload
protection is tripped, wait 5 minutes
and then reset the motor by pushing
in the red button. The arrow in
Figure 8 shows the location of the
reset button; located on the front of
the motor / pump facing towards you.
cleaning, and servicing the fryer.
move fryer without draining all frying compound from the tank.
When the fryer is cool, inspect annually. Check the flue and clear any obstructions.

Service in the US and Canada

Contact the Service Contractor in your area to obtain service and parts information. For a
complete listing of Service and Parts depots refer to www.vulcanequipment.com.
NO OR LOW GAS SUPPLY – If no action is taken after 90 seconds, an alarm sounds
continuously, the heat demand is disabled and any running cooking cycles are cancelled.
The digital display the following message:
VULCAN
Hot oil and hot parts can cause burns. Use care when operating,
Spilling hot fryer compound can cause severe burns. Do not

FLUE VENT INSPECTION

ALARMS AND ERROR MESSAGES

"D" Solid State – IGNITION LOCKOUT
"C" Computer – IGNITION LOCKOUT CHECK GAS SUPPLY

MAINTENANCE

Fig 8.
F-32971 Rev.U (12-17)