Vulcan-Hart VGCTS16 Service Manual

Round counter top tilting braising pans (16 gallon) gas and electric

Advertisement

VGCTS16 SHOWN ON STAND
This Manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly
qualified. If you have attended a Vulcan Service School for this
product, you may be qualified to perform all the procedures
described in this manual.
This manual is not intended to be all encompassing. If you have
not attended a Vulcan Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
Reproduction or other use of this Manual, without the express
written consent of Vulcan, is prohibited.
VULCAN-HART
A product of
Form 24643 (MARCH 1999)
SERVICE MANUAL
ROUND COUNTER TOP
TILTING BRAISING PANS
(16 GALLON)
GAS AND ELECTRIC
VGCTS16
VECTS16
- NOTICE -
ML-114827
ML-114825
LOUISVILLE, KY 40201-0696

Advertisement

Table of Contents
loading

Summary of Contents for Vulcan-Hart VGCTS16

  • Page 1 VGCTS16 ML-114827 VECTS16 ML-114825 VGCTS16 SHOWN ON STAND - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified. If you have attended a Vulcan Service School for this product, you may be qualified to perform all the procedures described in this manual.
  • Page 2: Table Of Contents

    ROUND TILTING BRAISING PANS TABLE OF CONTENTS GENERAL ................3 Introduction .
  • Page 3: General

    ROUND TILTING BRAISING PANS - GENERAL GENERAL INTRODUCTION The Vulcan round tilting braising pan (skillet) is a versatile piece of cooking equipment. It can be used to stew, simmer, sear, pan fry, grill or saute food products under an evenly distributed heating surface. Once the product is fully cooked, the pan can be tilted using the handle to empty the product from the pan.
  • Page 4: Specifications

    120V MODEL NAT. PROP. NAT. PROP. RECOMMEND RECOMMEND 60HZ VGCTS16 30,000 30,000 10.0 11.0 11.0 14.0 TOOLS Standard Standard set of hand tools. VOM with an AC current tester (meter sensitivity should be at least 20,000 ohms per volt can be used).
  • Page 5: Removal And Replacement Of Parts

    ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS REMOVAL AND REPLACEMENT OF PARTS Refer to the appropriate illustration for component location and identity. Only major components are covered by a replacement procedure. ILLUSTRATION - ELECTRIC MODEL Page 5 of 24...
  • Page 6: Illustration - Gas Model

    ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS ILLUSTRATION - GAS MODEL Page 6 of 24...
  • Page 7: Thermostats (Electric Model)

    ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS Disconnect heater lead wires and mark THERMOSTATS accordingly for proper replacement. (Electric Model) WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.
  • Page 8: Right And Left Console Cover

    ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS Disconnect the lead wires from the temperature RIGHT AND LEFT controller board. CONSOLE COVER Remove the mounting screws. Reverse procedure to install a new temperature WARNING: DISCONNECT THE ELECTRICAL controller and check for proper operation. POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX.
  • Page 9: Heater Contactors

    ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS Remove the screws securing the high limit to HEATING ELEMENTS the underside of the pan. Reverse procedure to install a new hi limit and WARNING: DISCONNECT THE ELECTRICAL check unit for proper operation. POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX.
  • Page 10: Pan Assembly

    ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS Remove those same components from the PAN ASSEMBLY underside of pan and set them aside for re-installing on replacement pan assembly. WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX.
  • Page 11: Bearings

    ROUND TILTING BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS Unbolt the braising pan from the mounting BEARINGS surface or stand. Lay the braising pan on its back to expose the WARNING: DISCONNECT THE ELECTRICAL four base plate mounting nuts and bolts. POWER TO THE MACHINE AT THE MAIN Remove the nuts and carriage bolts on the right CIRCUIT BOX.
  • Page 12: Service Procedures And Adjustments

    ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTS SERVICE PROCEDURES AND ADJUSTMENTS WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TEST OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.
  • Page 13: Flame Sense Probe (Gas Model)

    ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTS If the reading is less than 0.5 micro FLAME SENSE PROBE amps, turn thermostat and power (Gas Model) switch OFF. Check the flame sense probe for corrosion or grease build up and for loose or dirty connections on WARNING: THE FOLLOWING STEPS REQUIRE the terminal strips under the right and...
  • Page 14: Hot Surface Ignitor (Gas Model)

    ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTS HOT SURFACE IGNITOR TEMPERATURE CONTROLLER (GAS MODEL) AND POTENTIOMETER TEST (GAS MODEL) Check to see if hot surface ignitor is operating during ignition trial by: WARNING: THE FOLLOWING STEPS REQUIRE POWER TO BE APPLIED TO THE UNIT DURING Visual verification - HSI should be heating THE TEST.
  • Page 15: Heating Elements (Electric Model)

    ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTS Potentiometer HEATING ELEMENTS Perform the following test procedure to verify the (ELECTRIC MODEL) potentiometer is functioning properly and to confirm the temperature setting of the dial. A V-O-M connected from TC (-) to the wiper (red) on the WARNING: THE FOLLOWING STEPS REQUIRE potentiometer will read a voltage that corresponds to POWER TO BE APPLIED TO THE UNIT DURING...
  • Page 16: Electrical Operation

    ROUND TILTING BRAISING PANS - ELECTRICAL OPERATION ELECTRICAL OPERATION COMPONENT FUNCTION Heater Contactors ..Controls power to heating elements. (electric models only) Heating Elements (3) ..Heat the braising pan cooking surface. (electric models only) Transformer .
  • Page 17: Gas Model

    ROUND TILTING BRAISING PANS - ELECTRICAL OPERATION When burner lights, flame sense Gas Model probe detects flame, HSI de- Conditions. energizes after an 8.5 second ignition trial time, gas solenoid valve stays Unit connected to correct voltage, polarity open and heating begins. is correct and is properly grounded.
  • Page 18: Schematic Diagrams

    ROUND TILTING BRAISING PANS - ELECTRICAL OPERATION SCHEMATIC DIAGRAMS Electric Model Page 18 of 24...
  • Page 19: Gas Model

    ROUND TILTING BRAISING PANS - ELECTRICAL OPERATION Gas Model Page 19 of 24...
  • Page 20: Wiring Diagrams

    ROUND TILTING BRAISING PANS - ELECTRICAL OPERATION WIRING DIAGRAMS Electric Model (208/240V) Page 20 of 24...
  • Page 21: Electric Model (480V)

    ROUND TILTING BRAISING PANS - ELECTRICAL OPERATION Electric Model (480V) Page 21 of 24...
  • Page 22: Gas Model

    ROUND TILTING BRAISING PANS - ELECTRICAL OPERATION Gas Model Page 22 of 24...
  • Page 23: Troubleshooting

    ROUND TILTING BRAISING PANS - TROUBLESHOOTING TROUBLESHOOTING ALL MODELS WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TESTS OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.
  • Page 24: Gas Models Only

    ROUND TILTING BRAISING PANS - TROUBLESHOOTING GAS MODELS ONLY SYMPTOM POSSIBLE CAUSES Burner won’t light. Gas not on. Pan not down to close limit switch. Unit not properly grounded and/or polarity of incoming power is incorrect. Low incoming gas pressure. Gas solenoid valve malfunction.