task. Otherwise, the boot watchdog might initiate a system reboot before the
flash process is complete.
CAUTION
An incomplete firmware upgrade process may render the server
inaccessible or result in damaged/destroyed hardware.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface.
Disabling the boot watchdog in the BIOS
▶ Enter the BIOS.
▶ Select the Server Mgmt menu.
▶ Under Boot Watchdog set the Action setting to Continue.
▶ Save your changes and exit the BIOS.
For more information on BIOS settings, see the corresponding BIOS
Setup Utility reference manual.
Disabling the boot watchdog using the iRMC web interface
▶ Log in to the ServerView iRMC web interface.
▶ Select the Settings menu.
▶ Open the Server Management page.
▶ In the Boot Watchdog group, check the Enable Boot Watchdog option.
The Enable Boot Watchdog option must be selected.
▶ Select Continue from the Watchdog Action list.
▶ Click Apply for the changes to take effect.
For more information on iRMC settings, see the iRMC user guides.
RX4770 M5
Upgrade and Maintenance Manual
Basic software procedures
87