Appendix A
Status
flashing orange
HDD/SSD activity indicator (4)
Status
flashing green
Power-on indicator (5)
Status
off
green on
flashing green slowly
418
Description
Non-CSS component failure detected.
Possible causes:
– System is out of the specified temperature range
– Defective sensor
– CPU error
– Error detected by server management software
Description
Data access in progress.
Description
The server is switched off.
– The server has been switched on but Power Cycle
Delay settings delay it from turning on for a
specified time.
– The server is switched on and operating normally.
The BMC firmware is starting up after the server has
been connected to the mains.
Upgrade and Maintenance Manual
RX4770 M5