❷
Take care not to allow the cord to be caught under reactor cover ❷ .
Pass the power cord through cord bushing . Then, insert the power cord into the slit portion
of reactor cover ❷ and hold it with reactor base asm. ❸ .
❷
❹
Undersurface of table
Power box
❸
Operator's side
❶
220-250mm
❸
10)Take out reactor cover fixing screws from screw
bag ❹ . Secure reactor cover ❷ to reactor base
asm. ❸ with the fixing screws (at four locations).
11) Install accessory ring cores .
For two ring cores , clamp the power cord of
the electrical box after winding the cable round the
torus of the ring core twice.
12) Fix input/output cables and of reactor box
❶ on the table stand using accessory cord staple
.
At this time, take care not to cross the input- and
output-cables .
– 8 –
9) Fit reactor cover ❷ over reac-
tor base asm. ❸ .