JUKI DDL-8000AS Instruction Manual page 45

Table of Contents

Advertisement

No.
Item
P70
Machine head selection
(Initialization of data)
P72
Adjustment mode for the
needle-up stop angle
P73
Adjustment mode for the
needle-down stop angle
P74
Back-tack solenoid OFF
parameter
P75
Back-tack solenoid OFF
parameter
P76
Back-tack solenoid ON
parameter
P77
Back-tack solenoid ON
timing at the end of sewing
P78
Thread clamp ON angle
P79
Thread clamp OFF angle
P93
Reaction time when the
back part of pedal is de-
pressed
P109
Wiper operation timing
P110
Waiting time until the sewing
machine starts next sewing
P113
Bobbin counter
P114
Reverse feed solenoid oper-
ation stopping angle (start)
P115
Reverse feed solenoid oper-
ation stopping angle (end)
P116
Function of prohibiting the
correction operation after
turning the handwheel by
hand
P117
Thread trimming operation
after turning the handwheel
by hand
P118
Setting of the needle up/
down switch operation after
thread trimming
P128
Number of condensation
stitches at the beginning of
sewing
P129
Number of condensation
stitches at the end of sewing
P130
Condensation stitching
speed at the end of sewing
* Do not change the set values with asterisk (*) mark as they are functions for maintenance. If the standard set value set at the time
of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated. If it is necessary to
change the set value, please purchase the Engineer's Manual and follow the instructions.
Description
Machine head type is selected with this function setting item.
2: DDL-8000ASMS
3: DDL-8000ASSH
4: DDL-8000ABMS
5: DDL-8000ABSH
6: DDL-8000ASSJ
7: DDL-8000ABSJ
8: DDL-8000ASMS(CE)
9: DDL-8000ASSH(CE)
10: DDL-8000ABMS(CE)
11: DDL-8000ABSH(CE)
12: DDL-8000ASSJ(CE)
13: DDL-8000ABSJ(CE)
* When you select the corresponding machine head and press
the enter switch, all existing data are initialized to the initial
values for the machine head you have selected.
The current main shaft angle is always displayed in the data
display section. When you turn the pulley to bring the main shaft
to the needle-up stop position and press the enter switch, the
needle-up angle and needle-down angle of the main shaft are
automatically set.
The current main shaft angle is always displayed in the data
display section. When you turn the pulley to bring the main shaft
to the needle-down stop position and press the enter switch, the
only the needle-down angle of the main shaft is automatically set.
Back-tack solenoid OFF parameter
* Refer to the explanation of operation of the BT solenoid in the
Engineer's Manual for details.
Back-tack solenoid OFF parameter
* Refer to the explanation of operation of the BT solenoid in the
Engineer's Manual for details.
Back-tack solenoid ON parameter
* Refer to the explanation of operation of the BT solenoid in the
Engineer's Manual for details.
The BT solenoid ON timing at the end of sewing is set with this
function setting item.
* This parameter applies only to the free stitching.
ON-angle of the thread clamp is set with this function setting item.
OFF-angle of the thread clamp is set with this function setting
item.
The reaction time required to start lifting of the presser foot after
the back part of the pedal is depressed is set with this function
setting item.
The waiting time required until the wiper starts operation after the
sewing machine stops with its needle up.
The waiting time required until the sewing machine starts next
sewing after the thread trimming solenoid is turned OFF.
The largest value that the bobbin counter can count is set with this
function setting item.
0: Bobbin counter OFF
1 to 9999: Count-up value
The angle at which the solenoid output is prohibited (start) after
pressing the reverse-feed stitching on the way switch.
The angle at which the solenoid output is prohibited (end) after
pressing the reverse-feed stitching on the way switch.
The correction stitching function when turning the pulley by hand
upon completion of the polygonal-shape stitching is set with this
function setting item.
0: Correction sewing function is enabled
1: Correction sewing function is disabled
The thread trimming operation after turning the pulley by hand to
move the sewing machine from the upper and lower positions is
set with this function setting item.
0: Thread trimming operation is carried out after turning the
pulley by hand
1: Thread trimming operation is not carried out after turning the
pulley by hand.
The operation of the needle up/down switch after thread trimming
is set with this function setting item.
0: Needle up/down operation is carried out
1: One-stitch operation is carried out
The number of condensation stitches at the beginning of sewing
is set with this function setting item.
The number of condensation stitches at the end of sewing is set
with this function setting item.
The sewing speed for condensation stitching at the end of sewing
is set with this function setting item.
– 42 –
Level
Setting range
Default
S
2-13
2
S
0-1439
(1/4°)
S
0-1439
(1/4°)
S
0-990
3
S
0-990
10
S
10-990
200
U
50-500
150
U
0-359
190
(°)
U
0-359
300
(°)
S
10-990(ms)
100
S
5-990
5
S
0-500
250
U
0-9999
0
(10 stitches)
0-359 (°)
S
262
0-359 (°)
S
112
U
0-1
0
U
0-1
1
U
0-1
0
U
0-5(stitches)
0
U
0-5(stitches)
SMS, SSH,
SSJ:0
BMS, BSH,
BSJ:2
U
100-1900
310
(sti/min)

Advertisement