3.16 CNC Interface

The Gas Controller provides an optional CNC interface (P6) for legacy products and
robotic applications. Refer to Appendix B to interface with an Inova System. The
following I/O is provided:
• Start Input (24Vdc, 20ma)
o Pin 1 (+), Pin 2 (-)
• Transferred Arc Output (24Vdc, 20mA)
o Pin 3 (+), Pin 4 (-)
o Turns on upon transferred arc by default
o Logic can be inverted
• Plate Sense Output (24Vdc, 20mA)
o Pin 5 (+), Pin 6 (-)
o Turns on upon sensing plate by default
o Logic can be inverted
• Arc Voltage Output
o Pin 7 (+), Pin 8 (-)
o Arc voltage is represented as a current output 0 – 20mA.
o Output Voltage ratio is a function of load resistance.
o Max Resistance = 1000 Ohms (20:1 Ratio)
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
400V => 20mA output
 R
= 500 Ohms; 400V
load
Ratio = 400V/10V or 40:1
 R
= 250 Ohms; 400V
load
Ratio = 400V/5V or 80:1
P6
Page 52 of 132
BK8053-000111 Rev D
= 20mA x 500 Ohms = 10V
arc
= 20mA x 250 Ohms = 5V
arc