4.3 FineLine User Interface – Operation
4.3.1 Overview
The FineLine User Interface (UI) runs on an HMI, which can be a CNC Controller or
Industrial Computer. Since the HMI may include a touch screen interface, "press"
and "click" are used interchangeably to describe interacting with the FineLine UI.
The System is capable of several different plasma processes; however, "cutting" will
be used generically to describe the user interface:
• Cutting completely severs solid material, like plate and structural steel.
• Marking creates a noticeable mark in the material surface without cutting all
the way through the metal.
• Grid cuts through a non-continuous workpiece, like expanded metal.
Block Diagram
The following high-level sequence shows the steps required to prepare the System
to cut using the FineLine UI. Each step is described in detail later in this section.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
1) Choose Settings (see Section 4.4)
Select Units of Measure (Imperial / Metric)
Select Marking Gases (N2/N2 or Ar/Air)
2) Configure Plasma Setup (see Section 4.3.2)
Select Active Torch (for multi-torch setups)
Select Process – Cutting, Marking, or Grid
Select Material Type
Select Material Thickness
Select Current
3) Install Consumables (see Section 4.3.3)
Install consumables based on selected
configuration.
4) Configure CNC / Height Control (see Section 4.3.4)
Configure per Parameters Screen
5) Turn on the System (see Section 4.3.6)
System energizes and automatically
purges gases
Status bar displays "Ready to Cut"
Page 67 of 132
FineLine 170HD Plasma System

Advertisement

Table of Contents
loading

Table of Contents