Lincoln Electric FineLine 170HD Operator's Manual page 103

Table of Contents

Advertisement

BK8053-000111 Rev D
Source FL3HD
Event Code
1
8
64
128
256
512
1024
8192
16384
524288
1048576
2097152
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Status
Description
Light
Switchboard A Primary
311
Over Current
741
Switchboard A Fault
54
Secondary Over Current
71
Secondary Over Power
36
Thermal Fault
76
Pilot Board Fault
Switchboard A Softstart
761
Precharge Error
Switchboard A Cap Over
32
Voltage
Switchboard A Cap Under
34
Voltage
733
Switchboard Missing
High Cap Voltage
43
Differential
Coolant Temperature Too
817
High
Page 103 of 132
FineLine 170HD Plasma System
Possible Resolution
Report issue to Lincoln Electric
service department.
Report issue to Lincoln Electric
service department.
Report issue to Lincoln Electric
service department.
Report issue to Lincoln Electric
service department.
1) Check for blockage of the vents in
the sheet metal enclosure.
2) Check operation of internal fans.
3) Ensure within operating limits.
4) Using clean, dry, compressed air
(30 psi maximum), blow out all
accumulated dust inside the unit.
Check wiring to pilot PCB.
Report issue to Lincoln Electric
service department.
Report issue to Lincoln Electric
service department.
Report issue to Lincoln Electric
service department.
Report issue to Lincoln Electric
service department.
Report issue to Lincoln Electric
service department.
Note: The coolant pump will run until
the coolant temperature returns to
normal.
1) Check for blockage of the vents in
the sheet metal enclosure.
2) Check operation of internal fans.
3) Ensure within operating limits.
4) Check the routing of hoses and
leads are not near an external heat
source.